We present the articles of the third issue of scientific journal "Mining Science and Technologyβ (Russia) for 2024:
The resulting model can be used for general analysis of operability and stability, as well as for verifying the correct selection of key elements in the design of sucker-rod pump unit systems with variable frequency drives.
For more information, see the article:
π Ershov M.S., Efimov E.S. Stability of a controlled sucker-rod pump unit drive under operating conditions and during voltage dips in the electrical network. Mining Science and Technology (Russia). 2024;9(3):292-303. https://doi.org/10.17073/2500-0632-2024-01-213
Subscribe to the journal's Telegram channel:
πt.iss.one/MinSciTechπ
#inenglish #MST #pump #drive #control #voltage #frequency #brake #mode #energy #network #generator #current #torque #power #speed #rectifier #inverter #battery #signal #model #Matlab #Simulink #algorithm #emergency #protection #recovery #compensation #load #fluctuations #stability
The resulting model can be used for general analysis of operability and stability, as well as for verifying the correct selection of key elements in the design of sucker-rod pump unit systems with variable frequency drives.
For more information, see the article:
π Ershov M.S., Efimov E.S. Stability of a controlled sucker-rod pump unit drive under operating conditions and during voltage dips in the electrical network. Mining Science and Technology (Russia). 2024;9(3):292-303. https://doi.org/10.17073/2500-0632-2024-01-213
Subscribe to the journal's Telegram channel:
πt.iss.one/MinSciTechπ
#inenglish #MST #pump #drive #control #voltage #frequency #brake #mode #energy #network #generator #current #torque #power #speed #rectifier #inverter #battery #signal #model #Matlab #Simulink #algorithm #emergency #protection #recovery #compensation #load #fluctuations #stability
mst.misis.ru
Stability of a controlled sucker-rod pump unit drive under operating conditions and during voltage dips in the electrical networkβ¦
β€2π2β‘1π₯1π1
How to improve power quality in variable-frequency drives for scraper conveyors?
π Challenge:
Modern mines are actively implementing VFDs for scraper conveyors. However, this introduces voltage and current distortions, reducing energy efficiency and safety.
π Research:
Scientists from MISIS analyzed harmonic distortions in MPDS and evaluated the effectiveness of HFs, reactors, and SFs.
πΉ Key Findings:
βοΈ HFs and reactors reduce harmonics upstream of the FC by 70β90%.
βοΈ SFs mitigate distortions downstream of the FC but require precise tuning.
βοΈ Harmonics in leakage circuits (especially 3rd, 5th, 7th) impact RCDs and personnel safety.
βοΈ Combined use of HFs, reactors, and SFs delivers optimal results but needs technical-economic justification.
β οΈ Risks:
Higher harmonics in leakage circuits pose safety hazards and disrupt protective devices.
π‘ Recommendations:
1οΈβ£ Deploy HFs and reactors to suppress harmonics upstream of the FC.
2οΈβ£ Carefully select SF parameters.
3οΈβ£ Account for harmonics when configuring RCDs.
4οΈβ£ Implement real-time power quality monitoring.
π Conclusion:
Enhancing power quality in VFD-driven scraper conveyors demands a holistic approach and adaptive protection systems.
For more information, see the article:
π Petrov V.L., Pichuev A.V. Assessing the efficiency of measures to enhance electric power quality in variable-frequency drive for scraper conveyors. Mining Science and Technology (Russia). 2024;9(1):60-69. https://doi.org/10.17073/2500-0632-2024-01-198
How do you address these challenges? Share your insights below!
Subscribe to our Telegram channel:
π t.iss.one/MinSciTech π
#InEnglish #MST #PowerEngineering #MiningTechnology #VFD #ElectricalSafety #PowerQuality #MPDS #HF #Reactor #SineFilter #RCD #Harmonics #Distortion #Voltage #Current #FrequencyConverter #AVI #PWM #UndergroundNetworks #EnergyEfficiency #Protection #Modeling #GOST #Insulation #Compensation #Filtration #MISIS #Research #PracticalSolutions
π Challenge:
Modern mines are actively implementing VFDs for scraper conveyors. However, this introduces voltage and current distortions, reducing energy efficiency and safety.
π Research:
Scientists from MISIS analyzed harmonic distortions in MPDS and evaluated the effectiveness of HFs, reactors, and SFs.
πΉ Key Findings:
βοΈ HFs and reactors reduce harmonics upstream of the FC by 70β90%.
βοΈ SFs mitigate distortions downstream of the FC but require precise tuning.
βοΈ Harmonics in leakage circuits (especially 3rd, 5th, 7th) impact RCDs and personnel safety.
βοΈ Combined use of HFs, reactors, and SFs delivers optimal results but needs technical-economic justification.
β οΈ Risks:
Higher harmonics in leakage circuits pose safety hazards and disrupt protective devices.
π‘ Recommendations:
1οΈβ£ Deploy HFs and reactors to suppress harmonics upstream of the FC.
2οΈβ£ Carefully select SF parameters.
3οΈβ£ Account for harmonics when configuring RCDs.
4οΈβ£ Implement real-time power quality monitoring.
π Conclusion:
Enhancing power quality in VFD-driven scraper conveyors demands a holistic approach and adaptive protection systems.
For more information, see the article:
π Petrov V.L., Pichuev A.V. Assessing the efficiency of measures to enhance electric power quality in variable-frequency drive for scraper conveyors. Mining Science and Technology (Russia). 2024;9(1):60-69. https://doi.org/10.17073/2500-0632-2024-01-198
How do you address these challenges? Share your insights below!
Subscribe to our Telegram channel:
π t.iss.one/MinSciTech π
#InEnglish #MST #PowerEngineering #MiningTechnology #VFD #ElectricalSafety #PowerQuality #MPDS #HF #Reactor #SineFilter #RCD #Harmonics #Distortion #Voltage #Current #FrequencyConverter #AVI #PWM #UndergroundNetworks #EnergyEfficiency #Protection #Modeling #GOST #Insulation #Compensation #Filtration #MISIS #Research #PracticalSolutions